| LPV-60-12 | LPV-60-24
| LPV-60-5 |
| |
| Voltage:
| DC12V
| DC24V | DC5V |
| Rated Current:
| 5A | 2.5A | 8A |
| Current Range: | 0∽5A | 0∽2.5A | 0∽8A |
| Rated Power:
| 60W | 60W | 40W |
| Ripple & Noise(max.):
| 120mVp-p | 150mVp-p | 80mVp-p |
| Voltage Tolerance:
| ±5.0% | ±5.0% | ±8.0% |
| Line Regulation:
| ±1.0% | ±1.0% | ±1.0% |
| Load Regulation:
| ±2.0% | ±2.0% | ±6.0% |
| Setup,Rise Time:
| 500ms, 20ms / 230VAC 500ms,20ms / 115VAC at full load
|
| Hold Up Time(Typ.):
| 50ms/230VAC 16ms/115VAC at full load
|
| Voltage Range:
| 90∽264VAC |
Frequency Range:
| 47∽63HZ |
Efficiency (Typ.):
| 83% | 86% | 76% |
AC Current (Typ.):
| 1.2A / 115VAC 1A / 230VAC
|
Inrush Current (Typ.):
| Cold Start 70A(twidth=215us measured at 50% Ipeak) at 230vac
|
Max. No. of PSUs on 16A circuit breaker:
| 8 units (Circuit breaker of type B) / circuit breaker of type C ) at 230VAC
|
Leakage Current :
| 0.25mA / 240VAC
|
| Over Load:
| 110- 150% rated output power
|
Over Voltage Range::
| 13.8 ∽16V
| 28∽32V | 2.75∽6.75V |
Protection Type :
| Shut off O/P voltage , Clamping by zener diode
|
| Working Temp.
| -30 ∽ +70℃
|
Working Humidity:
| 20 ∽ 90 RH non-condensing
|
Storage Temp. Humidity:
| -40 ∽ +80℃ , 10 ∽ 95% RH
|
Temp. Coeeficient:
| ±0.03% (0∽ 50℃) |
Vibration: | 10∽500Hz, 2G 10min. / 1cycle,period for 60mis.
|
| Safety Standards:
| UL879, UL1310,CSA C22.2 No. 207-m89,Can/CSA C22.2 No. 223-M91 , TUV EN60950-1, IP67 approved
|
Withstand Voltage
| I/P - O/P :3KVAC
|
Isolation Resistance:
| I/P - O/P : >100M ohms / 500VDC / 25℃ / 70% RH
|
EMC emission:
| Compliance to EN55022 Class B, EN6100-3-2 Class A,EN6100-3-3
|
EMC Immunity
| Compliance to EN6100-4-2,3,4,5,6,8,11,EN55024,light industry level,criteria A
|